Skip to main content
To top

Liquid Processing

High Capacity Russell

Inline Filter

In line liquid filtration for flow rates up to 200,000 l/h

All self cleaning filters

High capacity inline strainer

The 900 Series Self Cleaning Russell Eco Filter® is a heavy duty industrial inline strainer developed for demanding applications with high flow requirements. The filter is used across a wide range of processes, from liquid chocolate production to wastewater and water filtration.

These filters are available in both vertical and horizontal configurations, with flanged inlet and outlet connections in sizes 4", 6", and 8". The design allows for straightforward integration into existing pipework systems.

See all applications

Material  Aperture size Capacity Model
  µm kg/hr lbs/hr  
Liquid chocolate 400 1000 22000 EF803J
Emulsion paint 100 8000 77000 EF502
High temp. phenolic resins 400 16500 36500 EF803DJ
Plastisol based coating 150 6000 13200 EF603
Offset ink 50 3000 6600 EF803D

 

 

 

Ensures stable process quality Precise filtration down to 25 microns delivers consistent product quality while protecting downstream equipment and process integrity.
Contributes to high operational efficiency The SpiroKlene™ wiper system maintains constant flow and significantly reduces the risk of blockage.
Reduces maintenance and operating costs Reusable filter elements combined with a simple design enable fast cleaning and cost effective servicing.
Improves health, safety, and environmental conditions The fully enclosed construction eliminates vapour release and reduces operator exposure to liquids and chemicals.

Features & Benefits

How does it work?

The Self Cleaning Russell Eco Filter® is a fully enclosed unit that continuously removes contamination from liquids. The filter is fitted with a removable filter element featuring precisely defined apertures designed to retain solid particles.

To ensure consistent filtration performance, the filter element is continuously cleaned by an integrated wiper system. At the same time, retained particles and impurities are directed to a collection zone, where they can be removed without interrupting production.

 

Filter Model Screen Area Max Flow Rate Connection Size
ft² cm² gpm m³/h in mm
M.75-90 0.4 372 50 11 0.75 20
M1-90 0.4 372 75 17 1 25
M1.5-90 0.4 372 100 23 1.5 40
M2-90 0.4 372 100 23 2 50
ML1.5-90 1 929 150 34 1.5 40
ML2-90 1 929 200 45 2 50
ML3-90 1 929 200 45 3 80
ML4-90 1 929 200 45 4 100
A1-90 1 929 75 17 1 25
A1.5-90 1 929 150 34 1.5 40
A2-90 1 929 200 45 2 50
A3-90 1 929 200 45 3 80
B2-90 2 1858 200 45 2 50
B3-90 2 1858 300 68 3 75
B4-90 2 1858 400 91 4 100
C2-90 3 2787 200 45 2 50
C3-90 3 2787 300 68 3 80
C4-90 3 2787 500 114 4 100
C6-90 3 2787 600 136 6 150
C8-90 3 2787 600 136 8 200
CL2-90 4 3716 200 45 2 50
CL3-90 4 3716 300 68 3 80
CL4-90 4 3716 500 114 4 100
CL6-90 4 3716 800 182 6 150
CL8-90 4 3716 800 182 8 200
CXL3-90 5 4645 300 68 3 80
CXL4-90 5 4645 500 114 4 100
CXL6-90 5 4645 1000 227 6 150
CXL8-90 5 4645 1000 227 8 200
CXL10-90 5 4645 1000 227 10 250
D3-90 4.25 3948 300 68 3 80
D4-90 4.25 3948 500 114 4 100
D6-90 4.25 3948 850 193 6 150
D8-90 4.25 3948 850 193 8 200
E4-90 6.25 5806 500 114 4 100
E6-90 6.25 5806 1000 227 6 150
E8-90 6.25 5806 1250 284 8 200
E10-90 6.25 5806 1560 284 10 250
F4-90 8 7432 500 114 4 100
F6-90 8 7432 1000 227 6 150
F8-90 8 7432 2000 363 8 200
F10-90 8 7432 2000 363 10 250
F12-90 8 7432 2800 363 12 300

 

 

We help you find the right solution

Contact us by phone or email, and we will help you identify a filtration solution tailored to your requirements.

Contact our team

Links
Language