HiFlux Auto-line filters are manufactured from stainless acid-proof EN 1.4404 steel. The filter meets current standards and norms for pressure vessels, complies with the EMC directive and is CE labelled. The VLR-E filter is available ready for installation, complete with electronic controller and automatic drainvalve.
HiFlux Auto-line© filters are manufactured from stainless acid-proof EN 1.4404 steel.
The filter meets current standards and norms for pressure vessels, com-plies with the EMC directive and is CE labelled.
The VLR-E filter is available ready for installation, complete with electronic controller and automatic drain-valve.
Design pressure: | 10 bar |
Test pressure: | According to EN 13445 |
Max differential pressure: | 3,0 bar |
Max working temperature: | 80°C (Fluid grp. 2 and steam pre. < 0,5 bar) |
Volume: | 485,0 litres |
Weight: | 650 kg |
Power supply: | 3 x 230/400V, 50 Hz |
Luftforsyning: | 5-7 bar, filtreret |
Flange connection: | DN300 PN16 EN1092-1/11 |
Drain: | Rp2 eller DN50 PN16 EN1092-1/11 |
Sludgechamber volume: | 22,0 litres |
Filtration: | 100-150-200-300-500-1.000 mikron |
Capacity (at a viscosity of 1 cSt and as a pressure filter)
Diff. pressure | Strainer area cm² | 100 * | 150 * | 300 * | 500 * | 1000 * |
---|---|---|---|---|---|---|
0,20 | 14.400 | 700 | 700 | 729 | 729 | 729 |
0,15 | 14.400 | 552 | 576 | 600 | 600 | 600 |
0,10 | 14.400 | 432 | 471 | 471 | 471 | 471 |
0,05 | 14.400 | 333 | 363 | 363 | 363 | 363 |
*) Capacity in m³/h / micron
The filter should only be installed as a pressure filter in systems which have a positive overpressure (the surroundings must be taken into consideration).
All Auto-line© filters are standardly produced according to the pressure equipment directive 2014/68/EC article 4, section
General Numbers | |
---|---|
Max working temperature | 80 °C |
Skrapesystem | Roterende |
Capacity | 960 - 2000 m3/h |
Sludgechamber volume | 88 litres |
Filtration areal | 28.250 cm2 |
Weight | 1100 kg |
Drain | Ball valve Rp2 |
Max differential pressure | 3-6 bar |
Design Pressure | 6 bar |
Filtration Range | 100-150-200-300-500-1000 µm |
Flange connection | DN500 PN10 EN1092-1/01 |
Power supply | 3 x 400V |
Volume | 1270 litres |
Air supply | 6 bar, filtreret |